Lynx Power In
The Lynx Power In contains a positive and negative busbar with 4 connections for batteries, loads or chargers and a ground connection. It is part of the Lynx Distribution system.
The Lynx Distributor has a power LED and four fuse status indication LEDs.
The Lynx Power In is part of the Lynx Distribution System, a modular busbar system that incorporates DC connections, distribution, fusing, battery monitoring and/or Lithium battery management.Â
The Lynx Distribution System consist of the following parts:
Lynx Power In – A positive and negative busbar with 4 connections for batteries or DC equipment.
Lynx Distributor – A positive and negative busbar with 4 fused connections for batteries or DC equipment together with fuse monitoring.
Lynx Shunt VE.Can – A positive busbar with a space for a main system fuse and a negative busbar with a shunt for battery monitoring. It has VE.Can communication for monitoring and setup with a GX device.
Lynx Smart BMSÂ – For use together with Victron Energy Smart Lithium batteries. It contains a positive busbar with a contactor that is driven by a battery management system (BMS) and a negative busbar with a shunt for battery monitoring. It has Bluetooth communication for monitoring and setup via the VictronConnect App and VE.Can communication for monitoring with a GX device and the VRM portal.
A Lynx distribution system usually consists of a single Lynx Shunt VE.Can module or a single Lynx Smart BMS module.
The choice between a Lynx Shunt VE.Can or a Lynx Smart BMS depends on what type of batteries are used in the system. The Lynx Smart BMS can only be used with the Victron Energy Lithium Smart Batteries, while the Lynx Shunt VE.Can is suitable for all other batteries.
Then, single, multiple or a combination of Lynx Distributor modules and/or Lynx Power In modules are added.
Together they form a continuous negative and positive busbar with DC connections and, depending on the configuration, integrated fuses, a battery monitor and/or lithium battery management.
It is also possible to just use Lynx Power In modules and/or Lynx Distributor modules without a Lynx Smart BMS module or a Lynx Shunt VE.Can modules. This for situations where battery monitoring or battery management is not needed.
The Lynx Power In is rated for a nominal current of 1000A, for 12, 24 or 48 System voltages.
To give an idea of how much power the Lynx modules are rated at different voltages, see below table. The power rating will give you an indication how big the connected inverter/charger system can be. Keep in mind that if inverters or inverter/chargers are used, both the AC and DC system will be powered from the batteries. Also be aware that a Lynx Smart BMS or a Lynx Ion (now discontinued) can have a lower current rating. Power rating Lynx modules
 | 12V | 24V | 48V |
---|---|---|---|
1000A | 12kW | 24kW | 48kW |
Power | |
---|---|
Voltage range | 9 – 60Vdc |
Current rating | 1000A |
Connections | |
---|---|
Busbar | M8 |
Physical | |
---|---|
Enclosure material | ABS |
Enclosure dimensions (hxwxd) | 290 x 170 x 80mm |
Unit weight | 2.1 kg |
Busbar material | Tinned copper |
Busbar dimensions (hxw) | 8 x 30mm |
Environmental | |
---|---|
Operating temperature range | -40°C to +60° |
Storage temperature range | -40°C to +60° |
Humidity | Max. 95%Â (non-condensing) |
Protection class | IP22 |
Purchase with confidence knowing your product is covered by the Victron 5-year manufacturer warranty.